A transformer is an electrical device that transfers energy from one circuit to another by magnetic coupling with no moving parts. A transformer comprises two or more coupled windings, or a single tapped winding and, in most cases, a magnetic core to concentrate magnetic flux. An alternating current in one winding creates a time-varying magnetic flux in the core, which induces a voltage in the other windings. Transformers are used to convert between high and low voltages, to change impedance, and to provide electrical isolation between circuits.
The transformer is one of the simplest of electrical devices. Its basic design, materials, and principles have changed little over the last one hundred years, yet transformer designs and materials continue to be improved. Transformers are essential for high voltage power transmission, providing an economical means of transmitting power over large distances. The simplicity, reliability, and economy of conversion of voltages by transformers was the principal factor in the selection of alternating current power transmission in the "War of Currents" in the late 1880s.
Audio-frequency transformers, then referred to as repeating coils, were used by the earliest experimenters in the development of the telephone. While some early electronics applications of the transformer have been replaced by alternative techniques, transformers are still found in many electronic devices.
Transformers come in a range of sizes from a thumbnail-sized coupling transformer hidden inside a stage microphone to huge gigawatt units used to interconnect large portions of national power grids. All operate with the same basic principles and with many similarities in their parts. Transformers alone cannot do the following:
However, transformers are components of the systems that perform all these functions.The gear ratio is equivalent to the transformer step-up or step-down ratio. A step-up transformer acts analogously to a reduction gear (in which mechanical power is transferred from a small, rapidly rotating gear to a large, slowly rotating gear): it trades current (speed) for voltage (torque), by transferring power from a primary coil to a secondary coil having more turns. A step-down transformer acts analogously to a multiplier gear (in which mechanical power is transferred from a large gear to a small gear): it trades voltage (torque) for current (speed), by transferring power from a primary coil to a secondary coil having fewer turns.
where
Saying that the primary and secondary windings are perfectly coupled is equivalent to saying that . Substituting and solving for the voltages shows that:
where
Hence in an ideal transformer, the ratio of the primary and secondary voltages is equal to the ratio of the number of turns in their windings, or alternatively, the voltage per turn is the same for both windings. The ratio of the currents in the primary and secondary circuits is inversely proportional to the turns ratio. This leads to the most common use of the transformer: to convert electrical energy at one voltage to energy at a different voltage by means of windings with different numbers of turns. In a practical transformer, the higher-voltage winding will have more turns, of smaller conductor cross-section, than the lower-voltage windings.
The EMF in the secondary winding, if connected to an electrical circuit, will cause current to flow in the secondary circuit. The MMF produced by current in the secondary opposes the MMF of the primary and so tends to cancel the flux in the core. Since the reduced flux reduces the EMF induced in the primary winding, increased current flows in the primary circuit. The resulting increase in MMF due to the primary current offsets the effect of the opposing secondary MMF. In this way, the electrical energy fed into the primary winding is delivered to the secondary winding.
For example, suppose a power of 50 watts is supplied to a resistive load from a transformer with a turns ratio of 25:2.
Transformers should not be driven with DC nor, generally, have any DC component present at the input. Relatively small amounts of direct current can cause core saturation and thus prevent proper operation. Also, since a DC voltage source would not give a time-varying flux in the core, no induced counter-EMF would be generated and so current flow into the transformer would be limited only by the series resistance of the windings. In this situation, the transformer would heat until the transformer either reaches thermal equilibrium or is destroyed. This principle is actually exploited when large power transformers must be dried (have condensation and other water removed from their windings) -- they are simply heated using DC.
For the exact same reason, transformers should generally not have DC components present in their output windings. The one notable violation of this rule occurs with half-wave rectifiers, but these circuits are usually extremely limited in output power anyway. Full-wave rectifiers, by comparison, impose no DC component on the transformer and so are capable of much higher power levels.
Those credited with the invention of the transformer include:
Many others have patents on transformers.
| Transformer with two windings and iron core. |
| Transformer with three windings. The dots show the adjacent ends of the windings. |
| Step-down or step-up transformer. The symbol shows which winding has more turns, but does not usually show the exact ratio. |
| Transformer with electrostatic screen, which prevents capacitive coupling between the windings. |
Transformer losses arise from:
Operation of a power transformer at other than its design frequency may require assessment of voltages, losses, and cooling to establish if safe operation is practical. For example, transformers at hydroelectric generating stations may be equipped with over-excitation protection, so-called "volts per hertz" protection relays, to protect the transformer from overvoltage at higher-than-rated frequency which may occur if a generator loses its connected load.
A steel core's magnetic hysteresis means that it retains a static magnetic field when power is removed. When power is then reapplied, the residual field will cause a high inrush current until the effect of the remanent magnetism is reduced, usually after a few cycles of the applied alternating current. Overcurrent protection devices such as fuses must be selected to allow this harmless inrush to pass. On transformers connected to long overhead power transmission lines, induced currents due to geomagnetic disturbances during solar storms can cause saturation of the core, and false operation of transformer protection devices.
Distribution transformers can achieve low off-load losses by using cores made with amorphous (non-crystalline) steel, so-called "metal glasses" — the high cost of the core material is offset by the lower losses incurred at light load, over the life of the transformer. In order to maintain good voltage regulation, distribution transformers are designed to have very low leakage inductance.
Certain special purpose transformers use long magnetic paths, insert air gaps, or add magnetic shunts (which bypass a portion of magnetic flux that would otherwise link the primary and secondary windings) in order to intentionally add leakage inductance. The additional leakage inductance limits the secondary winding's short circuit current to a safe, or a controlled, level. This technique is used to stabilize the output current for loads that exhibit negative resistance such as electric arcs, mercury vapor lamps, and neon signs, or safely handle loads that may become periodically short-circuited such as electric arc welders.
At even higher, radio-frequencies (RF), other types of cores made from non-conductive magnetic ceramic materials, called ferrites, are common. Some RF transformers also have moveable cores (sometimes called slugs) which allow adjustment of the coupling coefficient (and bandwidth) of tuned radio-frequency circuits.
Toroidal transformers are built around a ring-shaped core, which is made from a long strip of silicon steel or permalloy wound into a coil, from powdered iron, or ferrite, depending on operating frequency. The strip construction ensures that the grain boundaries are optimally aligned, improving the transformer's efficiency by reducing the core's reluctance. The closed ring shape eliminates air gaps inherent in the construction of an EI core. The cross-section of the ring is usually square or rectangular, but more expensive cores with circular cross-sections are also available. The primary and secondary coils are often wound concentrically to cover the entire surface of the core. This minimises the length of wire needed, and also provides screening to minimize the core's magnetic field from generating electromagnetic interference.
Ferrite cores are used at higher frequencies, typically between a few tens of kilohertz to a megahertz, to reduce losses, physical size, and weight of switch-mode power supplies.
Toroidal transformers are more efficient (around 95%) than the cheaper laminated EI types. Other advantages, compared to EI types, include smaller size (about half), lower weight (about half), less mechanical hum (making them superior in audio amplifiers), lower exterior magnetic field (about one tenth), low off-load losses (making them more efficient in standby circuits), single-bolt mounting, and more choice of shapes. This last point means that, for a given power output, either a wide, flat toroid or a tall, narrow one with the same electrical properties can be chosen, depending on the space available. The main disadvantage is higher cost.
A drawback of toroidal transformer construction is the higher cost of windings. As a consequence, toroidal transformers are uncommon above ratings of a few kVA. Small distribution transformers may achieve some of the benefits of a toroidal core by splitting it and forcing it open, then inserting a bobbin containg primary and secondary windings.
When fitting a toroidal transformer, it is important to avoid making an unintentional short-circuit through the core. This can happen if the steel mounting bolt in the middle of the core is allowed to touch metalwork at both ends, which could result in a dangerously large current flowing in the bolt.
The conducting material used for the winding depends upon the application. Small power and signal transformers are wound with solid copper wire, insulated usually with enamel and sometimes additional insulation. Larger power transformers may be wound with wire, copper or aluminum rectangular conductors, or strip conductors for very heavy currents. High frequency transformers operating in the tens to hundreds of kilohertz will have windings made of Litz wire, to minimize the skin effect losses in the conductors. Large power transformers use multiply-stranded conductors as well, since even at low power frequencies non-uniform distribution of current would otherwise exist in high-current windings. Each strand is insulated from the others, and the strands are arranged so that either at certain points in the winding or throughout the winding, each portion occupies different relative positions in the complete conductor. This "transposition" equalises the current flowing in each strand of the conductor, and reduces eddy current losses in the winding itself. The stranded conductor is also more flexible than a solid conductor of similar size. (see reference (1) below)
For signal transformers the windings may be arranged in a way to minimise leakage inductance and stray capacitance, to improve high-frequency response.
The transformer may also be immersed in transformer oil that provides further insulation. To ensure that the insulating capability of the transformer oil does not deteriorate, the transformer casing is completely sealed against moisture ingress. The oil serves as both cooling medium to remove heat from the core and coil and as part of the insulation system.
Transformers may also be enclosed by magnetic shields, electrostatic shields, or both to prevent outside interference from affecting the operation of the transformer, or to prevent the transformer from affecting the operation of other devices (such as CRTs near the transformer).
Specific provision must be made for cooling of high-power transformers. Some dry transformers are enclosed in pressurized tanks and are cooled by nitrogen or sulfur hexafluoride gas.
The windings of high-power or high-voltage transformers are immersed in transformer oil—a highly-refined mineral oil that is stable at high temperatures. Large transformers to be used indoors must use a non-flammable liquid. Formerly, polychlorinated biphenyl (PCB) was used as it was not a fire hazard in indoor power transformers and it is highly stable. Due to the stability of PCB and its environmental accumulation, it is no longer permitted in new equipment. Today, nontoxic, stable silicone-based oils or fluorinated hydrocarbons may be used, where the expense of a fire-resistant liquid offsets additional building cost for a transformer vault. Other less-flammable fluids such as canola oil may be used but all fire resistant fluids have some drawbacks in performance, cost, or toxicity compared with mineral oil.
The oil cools the transformer, and provides part of the electrical insulation between internal live parts. It has to be stable at high temperatures so that a small short or arc will not cause a breakdown or fire. The oil-filled tank may have radiators through which the oil circulates by natural convection. Very large or high-power transformers (with capacities of millions of watts) may have cooling fans, oil pumps and even oil to water heat exchangers. Oil-filled transformers undergo prolonged drying processes, using vapor-phase heat transfer, electrical self-heating, the application of a vacuum, or combinations of these, to ensure that the transformer is completely free of water vapor before the cooling oil is introduced. This helps prevent electrical breakdown under load.
Oil-filled power transformers may be equipped with Buchholz relays - safety devices sensing gas build-up inside the transformer (a side effect of an electric arc inside the windings) and switching off the transformer.
Experimental power transformers in the 2 MVA range have been built with superconducting windings which eliminates the copper losses, but not the core steel loss. These are cooled by liquid nitrogen or helium.
An autotransformer has only a single winding, which is tapped at some point along the winding. AC or pulsed voltage is applied across a portion of the winding, and a higher (or lower) voltage is produced across another portion of the same winding. While theoretically separate parts of the winding can be used for input and output, in practice the higher voltage will be connected to the ends of the winding, and the lower voltage from one end to a tap. For example, a transformer with a tap at the center of the winding can be used with 230 volts across the entire winding, and 115 volts between one end and the tap. It can be connected to a 230 volt supply to drive 115 volt equipment, or reversed to drive 230 volt equipment from 115 volts. As the same winding is used for input and output, the flux in the core is partially cancelled, and a smaller core can be used. For voltage ratios not exceeding about 3:1, an autotransformer is cheaper, lighter, smaller and more efficient than a true (two-winding) transformer of the same rating.
In practice, transformer losses mean that autotransformers are not perfectly reversible; one designed for stepping down a voltage will deliver slightly less voltage than required if used to step up. The difference is usually slight enough to allow reversal where the actual voltage level is not critical.
By exposing part of the winding coils and making the secondary connection through a sliding brush, an autotransformer with a near-continuously variable turns ratio can be obtained, allowing for very small increments of voltage.
Examples:
Other applications of resonant transformers are as coupling between stages of a superheterodyne receiver, where the selectivity of the receiver is provided by the tuned transformers of the intermediate-frequency amplifiers.
A voltage regulating transformer uses a resonant winding and allows part of the core to go into saturation on each cycle of the alternating current. This effect stabilizes the output of the regulating transformer, which can be used for equipment that is sensitive to variations of the supply voltage. Saturating transformers provide a simple rugged method to stabilize an ac power supply. However, due to the hysteresis losses accompanying this type of operation, efficiency is low.
Current transformers are commonly used in electricity meters to facilitate the measurement of large currents which would be difficult to measure more directly.
Current transformers are often constructed by passing a single primary turn (either an insulated cable or a copper busbar) through a well-insulated toroidal core wrapped with many turns of wire. Current transformers are used extensively in the electrical power industry for monitoring of the power grid. The "CT" is described by its current ratio from primary to secondary. Common secondaries are 1 or 5 amperes. The winding often has several taps so that sensitivity to the load may be altered in the future. Often multiple CT's will be installed as a "stack" for various uses (for example, protection devices and revenue metering may use separate CTs). Specially constructed "wideband current transformers" are also used (usually with an oscilloscope) to measure waveforms of high frequency or pulsed currents. One type of specially constructed wideband transformer provides a voltage output that is proportional to the measured current. Another type (called a Rogowski coil) requires an external integrator in order to provide a voltage output that is proportional to the measured current.
Care must be taken that the secondary of a current transformer is not disconnected from its load while current is flowing in the primary as in this circumstance a dangerously high voltage can be produced across the open secondary.
To minimise distortion of the pulse shape, a pulse transformer needs to have low values of leakage inductance and distributed capacitance, and a high open-circuit inductance. In power-type pulse transformers, a low coupling capacitance (between the primary and secondary) is important to protect the circuitry on the primary side from high-powered transients created by the load. For the same reason, high insulation resistance and high breakdown voltage are required. A good transient response is necessary to maintain the rectangular pulse shape at the secondary, because a pulse with slow edges would create switching losses in the power semiconductors.
The product of the peak pulse voltage and the duration of the pulse (or more accurately, the voltage-time integral) is often used to characterise pulse transformers. Generally speaking, the larger this product, the larger and more expensive the transformer.
The core material increases the inductance dramatically, thereby raising its Q factor. The cores of such transformers help improve performance at the lower frequency end of the band. Older style RF transformers sometimes used a third coil (called a tickler winding) to inject feedback into an earlier (detector) stage in antique regenerative radio receivers.
Audio transformers are usually the factor which limit sound quality; electronic circuits with wide frequency response and low distortion are relatively simple to design.
Transformers are also used in DI boxes to match impedance from high impedance instruments (for example, bass guitars) to be able to connect them to a microphone input on the mixing console.
A particularly critical component is the output transformer of an audio power amplifier. Valve circuits for quality reproduction have long been produced with no other (inter-stage) audio transformers, but an output transformer is needed to couple the relatively high impedance (up to a few hundred ohms depending upon configutation) of the output valve(s) to the low impedance of a loudspeaker. (The valves can deliver a low current at a high voltage; the speakers require high current at low voltage.)
For good low-frequency response a relatively large iron core is required; high power handling increases the required core size. Low distortion requires iron of adequate properties; special cores with oriented magnetic domains are used for best results. Good high-frequency response requires carefully designed and implemented winding without excessive leakage inductance or stray capacitance. All this makes for an expensive component.
Output transformerless audio power valve amplifiers are possible (e.g., a design by Julius Futterman), but were rarely used due to other disadvantages.
Early transistor audio power amplifiers often had output transformers, but they were eliminated as designers discovered how to design amplifiers without them.
In the same way that transformers are used to create high voltage power transmission circuits that minimize transmission losses, speaker transformers allow many individual loudspeakers to be powered from a single audio circuit operated at higher-than normal speaker voltages. This application is common in public address (e.g., Tannoy) applications. Such circuits are commonly referred to as constant voltage or 70 volt speaker circuits although the audio waveform obviously is constantly changing voltage.
At the audio amplifier, a large audio transformer may be used to step-up the low impedance, low-voltage output of the amplifier to the designed line voltage of the speaker circuit. (For high-powered amps, the amplifier transformer may not be needed.) Then, a smaller transformer at each speaker returns the voltage and impedance to ordinary speaker levels. The speaker transformers commonly have multiple primary taps, allowing the volume at each speaker to be adjusted in a number of discrete steps.
Use of a constant voltage speaker circuit means that there is no need to worry about the impedance presented to the amplifier output (which would clearly be too low if all of the speakers were arranged in parallel and would be a too-complex design problem if the speakers were aranged in series-parallel). The use of higher transmission voltage and impedance means that power lost in the connecting wire is minimized, even with the use of small-gauge conductors (and leads to the term constant voltage as the line voltage doesn't change much as additional speakers are added to the system). Also, the ability to adjust, locally, the volume of each speaker (without the complexity and power loss of an L pad) is a useful feature.
Electronics | Transformers (electrical)
المحوّل | Transformador | Transformátor | Transformator | Transformator | Transformaator | Transformador | Transformatoro | Transformateur électrique | Transformador | Transformator | Trasformatore | שנאי | Transzformátor | Transformator | 変圧器 | Transformator | Transformator | Transformador | Трансформатор | Transformator | Transformátor | Transformator | Трансформатор | Muuntaja | Transformator | மின்மாற்றி | หม้อแปลงไฟฟ้า | Transformatör | 变压器
This article is licensed under the GNU Free Documentation License.
It uses material from the
"Transformer".