In computing, RAID (a redundant array of inexpensive disks, also later known as redundant array of independent disks) is a system which uses multiple hard drives to share or replicate data among the drives. Depending on the version chosen, the benefit of RAID is one or more of increased data integrity, fault-tolerance, throughput or capacity compared to single drives. In its original implementations, its key advantage was the ability to combine multiple low-cost devices using older technology into an array that offered greater capacity, reliability, speed, or a combination of these things, than was affordably available in a single device using the newest technology.
At the very simplest level, RAID combines multiple hard drives into a single logical unit. Thus, instead of seeing several different hard drives, the operating system sees only one. RAID is typically used on server computers, and is usually (but not necessarily) implemented with identically-sized disk drives. With decreases in hard drive prices and wider availability of RAID options built into motherboard chipsets, RAID is also being found and offered as an option in more advanced personal computers. This is especially true in computers dedicated to storage-intensive tasks, such as video and audio editing.
The original RAID specification suggested a number of prototype "RAID levels", or combinations of disks. Each had theoretical advantages and disadvantages. Over the years, different implementations of the RAID concept have appeared. Most differ substantially from the original idealized RAID levels, but the numbered names have remained. This can be confusing, since one implementation of RAID 5, for example, can differ substantially from another. RAID 3 and RAID 4 are often confused and even used interchangeably.
The very definition of RAID has been argued over the years. The use of the term redundant leads many to object to RAID 0 being called a RAID at all. Similarly, the change from inexpensive to independent confuses many as to the intended purpose of RAID. There are even some single-disk implementations of the RAID concept. For the purpose of this article, we will say that any system which employs the basic RAID concepts to combine physical disk space for purposes of reliability, capacity, or performance is a RAID system.
In 1988, RAID levels 1 through 5 were formally defined by David A. Patterson, Garth A. Gibson and Randy H. Katz in the paper, "A Case for Redundant Arrays of Inexpensive Disks (RAID)". This was published in the SIGMOD Conference 1988: pp 109–116. The term "RAID" was first introduced in this paper; it spawned the entire disk array industry.
With a software implementation, the operating system manages the disks of the array through the normal drive controller (IDE/ATA, SATA, SCSI, Fibre Channel, etc.). With present CPU speeds, software RAID can be faster than hardware RAID, though at the cost of using CPU power which might be best used for other tasks. One major exception is where the hardware implementation of RAID incorporates a battery backed-up write back cache which can speed up an application, such as an OLTP database server. In this case, the hardware RAID implementation flushes the write cache to secure storage to preserve data at a known point if there is a crash. The hardware approach is faster than accessing the disk drive and limited by RAM speeds, the rate at which the cache can be mirrored to another controller, the amount of cache and how fast it can flush the cache to disk. For this reason, battery-backed caching disk controllers are often recommended for high transaction rate database servers. In the same situation, the software solution is limited to no more flushes than the number of rotations or seeks per second of the drives. Another disadvantage of a pure software RAID is that, depending on the disk that fails and the boot arrangements in use, the computer may not be able to be rebooted until the array has been rebuilt.
A hardware implementation of RAID requires at a minimum a special-purpose RAID controller. On a desktop system, this may be a PCI expansion card, or might be a capability built in to the motherboard. In larger RAIDs, the controller and disks are usually housed in an external multi-bay enclosure. The disks may be IDE, ATA, SATA, SCSI, Fibre Channel, or any combination thereof. The controller links to the host computer(s) with one or more high-speed SCSI, Fibre Channel or iSCSI connections, either directly, or through a fabric, or is accessed as network attached storage. This controller handles the management of the disks, and performs parity calculations (needed for many RAID levels). This option tends to provide better performance, and makes operating system support easier. Hardware implementations also typically support hot swapping, allowing failed drives to be replaced while the system is running. In rare cases hardware controllers have become faulty, which can result in data loss. Hybrid RAIDs have become very popular with the introduction of inexpensive hardware RAID controllers. The hardware is a normal disk controller that has no RAID features, but there is a boot-time application that allows users to set up RAIDs that are controlled via the BIOS. When any modern operating system is used, it will need specialized RAID drivers that will make the array look like a single block device. Since these controllers actually do all calculations in software, not hardware, they are often called "fakeraids". Unlike software RAID, these "fakeraids" typically cannot span multiple controllers.
Both hardware and software versions may support the use of a hot spare, a preinstalled drive which is used to immediately (and almost always automatically) replace a drive that has failed. This reduces the mean time to repair period during which a second drive failure in the same RAID redundancy group can result in loss of data.
Some software RAID systems allow one to build arrays from partitions instead of whole disks. Unlike Matrix RAID they are not limited to just RAID 0 and RAID 1 and not all partitions need to be RAID.
Given the diagram below, assume A1 = 00000111, A2 = 00000101, and A3 = 00000000. Ap, generated by XORing A1, A2, and A3, will then equal 00000010. If the second drive fails, A2 will no longer be accessible, but can be reconstructed by XORing A1, A3, and Ap:
A1 XOR A3 XOR Ap = 00000101 (A2).
RAID Array A1 A2 A3 Ap B1 B2 Bp B3 C1 Cp C2 C3 Dp D1 D2 D3
Note: Data blocks are in the format A#, parity blocks Ap.
While the block size can technically be as small as a byte it is almost always a multiple of the hard disk sector size of 512 bytes. This lets each drive seek independently when randomly reading or writing data on the disk. If all the accessed sectors are entirely on one disk then the apparent seek time would be the same as a single disk. If the accessed sectors are spread evenly among the disks then the apparent seek time would be reduced by half for two disks, by two-thirds for three disks, etc., assuming identical disks. For normal data access patterns the apparent seek time of the array would be between these two extremes. The transfer speed of the array will be the transfer speed of all the disks added together, limited only by the speed of the RAID controller.
RAID 0 is useful for setups such as large read-only NFS servers where mounting many disks is time-consuming or impossible and redundancy is irrelevant. Another use is where the number of disks is limited by the operating system. In Microsoft Windows, the number of drive letters for hard disk drives may be limited to 24, so RAID 0 is a popular way to use more disks. It is possible in Windows 2000 Professional & newer to mount partitions under directories, much like Unix, and hence eliminating the need for a partition to be assigned a drive letter. RAID 0 is also a popular choice for gaming systems where performance is desired, data integrity is not very important, but cost is a consideration to most users. However, since data is shared between drives without redundancy, hard drives cannot be swapped out as all disks are dependent upon each other.
NOTE: Technical sites have stated that for home PCs, the speed advantages are only theoretical and aren't noticeable. See links below.
In this sense, concatenation is akin to the reverse of partitioning. Whereas partitioning takes one physical drive and creates two or more logical drives, JBOD uses two or more physical drives to create one logical drive.
In that it consists of an Array of Independent Disks (no redundancy), it can be thought of as a distant relation to RAID. JBOD is sometimes used to turn several odd-sized drives into one useful drive. Therefore, JBOD could use a 3 GB, 15 GB, 5.5 GB, and 12 GB drive to combine into a logical drive at 35.5 GB, which is often more useful than the individual drives separately.
JBOD is similar to the widely used Logical Volume Manager (LVM) and Logical Storage Manager (LSM) in UNIX and UNIX-based operating systems (OS). JBOD is useful for OSs which do not support LVM/LSM (like MS-Windows, although Windows 2003 Server, Windows XP Pro, and Windows 2000 support software JBOD, known as spanning dynamic disks). The difference between JBOD and LVM/LSM is that the address remapping between the logical address of the concatenated device and the physical address of the disc is done by the RAID hardware instead of the OS kernel as it is LVM/LSM.
One advantage JBOD has over RAID 0 is in the case of drive failure. Whereas in RAID 0, failure of a single drive will usually result in the loss of all data in the array, in a JBOD array only the data on the affected drive is lost, and the data on surviving drives will remain readable. However, JBOD does not carry the performance benefits which are associated with RAID 0.
Note: Some Raid cards (Ex. 3ware) use JBOD to refer to configuring drives without raid features including concatenation. Each drive shows up separately in the OS.
A RAID 1 creates an exact copy (or mirror) of a set of data on two or more disks. This is useful when read performance is more important than data capacity. Such an array can only be as big as the smallest member disk. A classic RAID 1 mirrored pair contains two disks, which increases reliability exponentially over a single disk. Since each member contains a complete copy of the data, and can be addressed independently, ordinary wear-and-tear reliability is raised by the power of the number of self-contained copies. For example, consider a model of disk drive with a weekly probability of failure of 1:500. Assuming defective drives are replaced weekly, a two-drive RAID 1 installation would carry a 1:250,000 probability of failure for a given week. That is, the chances that both drives experience an ordinary mechanical failure during the same week is the square of the chances for only one drive.
Additionally, since all the data exists in two or more copies, each with its own hardware, the read performance goes up roughly as a linear multiple of the number of copies. That is, a RAID 1 array of three drives can be reading in three different places at the same time. To maximize performance benefits of RAID 1, independent disk controllers are recommended, one for each disk. Some refer to this practice as splitting or duplexing. When reading, both disks can be accessed independently. Like RAID 0 the average seek time is reduced by half when randomly reading but because each disk has the exact same data the requested sectors can always be split evenly between the disks and the seek time remains low unlike RAID 0. The transfer rate would also be doubled. For three disks the seek time would be a third and the transfer rate would be tripled. The only limit is how many disks can be connected to the controller and its maximum transfer speed. Many older IDE RAID 1 cards read from one disk in the pair, so their read performance is that of a single disk. Some older RAID 1 implementations would also read both disks simultaneously and compare the data to catch errors. The error detection and correction on modern disks makes this less useful in environments requiring normal commercial availability. When writing, the array performs like a single disk as all mirrors must be written with the data.
RAID 1 has many administrative advantages. For instance, in some 365*24 environments, it is possible to "Split the Mirror": declare one disk as inactive, do a backup of that disk, and then "rebuild" the mirror. This requires that the application support recovery from the image of data on the disk at the point of the mirror split. This procedure is less critical in the presence of the "snapshot" feature of some filesystems, in which some space is reserved for changes, presenting a static point-in-time view of the filesystem. Alternatively, a set of disks can be kept in much the same way as traditional backup tapes are.
Also, one common practice is to create an extra mirror of a volume (also known as a Business Continuance Volume or BCV) which is meant to be split from the source RAID set and used independently. In some implementations, these extra mirrors can be split and then incrementally re-established, instead of requiring a complete RAID set rebuild.
In our example above, a request for block "A" consisting of bytes A1-A9, would require all three data disks to seek to the beginning (A1) and reply with their contents. A simultaneous request for block B would have to wait.
In our example above, a request for block "A1" would be serviced by disk 1. A simultaneous request for block B1 would have to wait, but a request for B2 could be serviced concurrently.
In the example above, a read request for block "A1" would be serviced by disk 1. A simultaneous read request for block B1 would have to wait, but a read request for B2 could be serviced concurrently.
Every time a block is written to a disk in a RAID 5, a parity block is generated within the same stripe. A block is often composed of many consecutive sectors on a disk. A series of blocks (a block from each of the disks in an array) is collectively called a "stripe". If another block, or some portion of a block, is written on that same stripe the parity block (or some portion of the parity block) is recalculated and rewritten. For small writes, this requires reading the old data, writing the new parity, and writing the new data. The disk used for the parity block is staggered from one stripe to the next, hence the term "distributed parity blocks". RAID 5 writes are expensive in terms of disk operations and traffic between the disks and the controller.
The parity blocks are not read on data reads, since this would be unnecessary overhead and would diminish performance. The parity blocks are read, however, when a read of a data sector results in a cyclic redundancy check (CRC) error. In this case, the sector in the same relative position within each of the remaining data blocks in the stripe and within the parity block in the stripe are used to reconstruct the errant sector. The CRC error is thus hidden from the main computer. Likewise, should a disk fail in the array, the parity blocks from the surviving disks are combined mathematically with the data blocks from the surviving disks to reconstruct the data on the failed drive "on the fly".
This is sometimes called Interim Data Recovery Mode. The computer knows that a disk drive has failed, but this is only so that the operating system can notify the administrator that a drive needs replacement; applications running on the computer are unaware of the failure. Reading and writing to the drive array continues seamlessly, though with some performance degradation. The difference between RAID 4 and RAID 5 is that, in interim data recovery mode, RAID 5 might be slightly faster than RAID 4, because, when the CRC and parity are in the disk that failed, the calculation does not have to be performed, while with RAID 4, if one of the data disks fails, the calculations have to be performed with each access.
In RAID 5, where there is a single parity block per stripe, the failure of a second drive results in total data loss.
The maximum number of drives in a RAID 5 redundancy group is theoretically unlimited, but it is common practice to limit the number of drives. The tradeoffs of larger redundancy groups are greater probability of a simultaneous double disk failure, the increased time to rebuild a redundancy group, and the greater probability of encountering an unrecoverable sector during RAID reconstruction. As the number of disks in a RAID 5 group increases, the MTBF can become lower than that of a single disk. This happens when the likelihood of a second disk failing out of (N-1) dependent disks, within the time it takes to detect, replace and recreate a first failed disk, becomes larger than the likelihood of a single disk failing. RAID 6 is an alternative that provides dual parity protection thus enabling larger numbers of disks per RAID group.
Some RAID vendors will avoid placing disks from the same manufacturing run in a redundancy group to minimize the odds of simultaneous early life and end of life failures as evidenced by the bathtub curve.
RAID 5 implementations suffer from poor performance when faced with a workload which includes many writes which are smaller than the capacity of a single stripe; this is because parity must be updated on each write, requiring read-modify-write sequences for both the data block and the parity block. More complex implementations often include non-volatile write back cache to reduce the performance impact of incremental parity updates.
In the event of a system failure while there are active writes, the parity of a stripe may become inconsistent with the data; if this is not detected and repaired before a disk or block fails, data loss may ensue as incorrect parity will be used to reconstruct the missing block in that stripe; this potential vulnerability is sometimes known as the "write hole". Battery-backed cache and other techniques are commonly used to reduce the window of vulnerability of this occurring.
RAID 5 can be seen as a special case of a Reed-Solomon code where the syndrome used is the one built from generator 1 H. Peter Anvin, "The mathematics of RAID-6". (online paper). Thus RAID 5 requires only addition in the galois field. Since we are operating on bytes, the field used is a binary galois field (), typically of order 8. In binary galois fields, addition is computed by a simple XOR.
After understanding RAID 5 as a special case of a Reed-Solomon code, it is easy to see that it is possible to extend the approach to produce redundancy simply by producing another syndrome using a different generator; for example, 2 in . By adding additional generators it is possible to achieve any number of redundant disks, and recover from the failure of that many drives anywhere in the array.
Like RAID 5 the parity is distributed in stripes, with the parity blocks in a different place in each stripe.
RAID 6 is inefficient when used with a small number of drives but as arrays become bigger and have more drives the loss in storage capacity becomes less important and the probability of two disks failing at once is bigger. RAID 6 provides protection against double disk failures and failures while a single disk is rebuilding. In the case where there is only one array it makes more sense than having a hot spare disk.
The user capacity of a RAID 6 array is n-2, where n is the total number of drives in the array.
RAID 6 does not have a performance penalty for read operations, but it does have a performance penalty on write operations due to the overhead associated with the additional parity calculations.
Nested RAIDs are usually signified by joining the numbers indicating the RAID levels into a single number, sometimes with a '+' in between. For example, RAID 10 (or RAID 1+0) conceptually consists of multiple level 1 arrays stored on physical disks with a level 0 array on top, striped over the level 1 arrays. In the case of RAID 0+1, it is most often called RAID 0+1 as opposed to RAID 01 to avoid confusion with RAID 1. However, when the top array is a RAID 0 (such as in RAID 10 and RAID 50), most vendors choose to omit the '+', though RAID 5+0 is more informative.
When nesting RAID levels, a RAID type that provides redundancy is typically combined with RAID 0 to boost performance. With these configurations it is preferable to have RAID 0 on top and the redundant array at the bottom, because fewer disks then need to be regenerated when a disk fails. (Thus, RAID 10 is preferable to RAID 0+1 but the administrative advantages of "splitting the mirror" of RAID 1 would be lost).
RAID 1 /
Note: A1, B1, et cetera each represent one data block; each column represents one disk.
The maximum storage space here is 360 GB, spread across two arrays. The advantage is that when a hard drive fails in one of the level 0 arrays, the missing data can be transferred from the other array. However, adding an extra hard drive to one stripe requires you to add an additional hard drive to the other stripes to balance out storage among the arrays.
It is not as robust as RAID 10 and cannot tolerate two simultaneous disk failures, if not from the same stripe. That is, once a single disk fails, each of the mechanisms in the other stripe is single point of failure. Also, once the single failed mechanism is replaced, in order to rebuild its data all the disks in the array must participate in the rebuild.
To add to the confusion, some controllers that run in RAID 0+1 mode combine the striping and mirroring into a single operation. The layout of the blocks for RAID 0+1 and RAID 10 are identical except that the disks are in a different order. To the smart controller this does not matter and they gain all the benefits of RAID 10 but are still labelled as only supporting RAID 0+1 in their documentation.
RAID 0 /
Note: A1, B1, et cetera each represent one data block; each column represents one disk.
All but one drive from each RAID 1 set could fail without damaging the data. However, if the failed drive is not replaced, the single working hard drive in the set then becomes a single point of failure for the entire array. If that single hard drive then fails, all data stored in the entire array is lost.
Extra 120 GB hard drives could be added to any one of the level 1 arrays to provide extra redundancy. Unlike RAID 0+1, all the "sub-arrays" do not have to be upgraded simultaneously.
RAID 10 is often the primary choice for high-load databases, because the lack of parity to calculate gives it faster write speeds.
RAID 10 Capacity: (Size of Smallest Drive) * (Even Number of Drives ) / 2
Advantages
RAID 30 can sustain one to four drive failures while maintaining data integrity if each failed disk is in a different RAID 3 array.
Offers highest level of redundancy and performance
Disadvantages
Very costly to implement
/
RAID 0 /
Note: A1, B1, et cetera each represent one data sector; each column represents one disk.
All but one drive from each RAID 1 set could fail without loss of data. However, the remaining disk from the RAID 1 becomes a single point of failure for the already degraded array. Often the top level stripe is done in software. Some vendors call the top level stripe a MetaLun, or a Soft Stripe.
The major benefits of RAID 100 (and plaid RAID in general) over single-level RAID are better random read performance and the mitigation of hotspot risk on the array. For these reasons, RAID 100 is often the best choice for very large databases, where the underlying array software limits the amount of physical disks allowed in each standard array. Implementing nested RAID levels allows virtually limitless spindle counts in a single logical volume.
Below is an example where three collections of 240 GB RAID 5s are striped together to add up to 720 GB of total storage space:
RAID 0 /
Note: A1, B1, et cetera each represent one data block; each column represents one disk; Ap, Bp, et cetera each represent parity information for each distinct RAID 5 and may represent different values across the RAID 0 (that is, Ap for A1 and A2 can differ from Ap for A3 and A4).
One drive from each of the RAID 5 sets could fail without loss of data. However, if the failed drive is not replaced, the remaining drives in that set then become a single point of failure for the entire array. If one of those drives fails, all data stored in the entire array is lost. The time spent in recovery (detecting and responding to a drive failure, and the rebuild process to the newly inserted drive) represents a period of vulnerability to the RAID set.
In the example below, datasets may be striped across both RAID sets. A dataset with 5 blocks would have 3 blocks written to the first RAID set, and the next 2 blocks written to RAID set 2. RAID Set 1 RAID Set 2 A1 A2 A3 Ap A4 A5 A6 Ap B1 B2 Bp B3 B4 B5 Bp B6 C1 Cp C2 C3 C4 Cp C5 C6 Dp D1 D2 D3 Dp D4 D5 D6
The configuration of the RAID sets will impact the overall fault tolerance. A construction of three seven-drive RAID 5 sets has higher capacity and storage efficiency, but can only tolerate three maximum potential drive failures. Because the reliability of the system depends on quick replacement of the bad drive so the array can rebuild, it is common to construct three six-drive RAID5 sets each with a hot spare that can immediately start rebuilding the array on failure. This does not address the issue that the array is put under maximum strain reading every bit to rebuild the array precisely at the time when it is most vulnerable. A construction of seven three-drive RAID 5 sets can handle as many as seven drive failures but has lower capacity and storage efficiency.
RAID 50 improves upon the performance of RAID 5 particularly during writes, and provides better fault tolerance than a single RAID level does. This level is recommended for applications that require high fault tolerance, capacity and random positioning performance.
As the number of drives in a RAID set increases, and the capacity of the drives increase, this impacts the fault-recovery time correspondingly as the interval for rebuilding the RAID set increases.
This is more easily illustrated using RAID 4, Twin Syndrome RAID 4 (RAID 6 with a RAID 4 layout which is not actually implemented), and double parity RAID 4.
Traditional Twin Syndrome Double parity RAID 4 RAID 4 RAID 4 A1 A2 A3 Ap A1 A2 A3 Ap Aq A1 A2 A3 Ap 1n B1 B2 B3 Bp B1 B2 B3 Bp Bq B1 B2 B3 Bp 2n C1 C2 C3 Cp C1 C2 C3 Cp Cq C1 C2 C3 Cp 3n D1 D2 D3 Dp D1 D2 D3 Dp Dq D1 D2 D3 Dp 4n
Note: A1, B1, et cetera each represent one data block; each column represents one disk.
The n blocks are the double parity blocks. The block 2n would be calculated as A2 xor B3 xor Cp, while 3n would be calculated as A3 xor Bp xor C1 and 1n would be calculated as A1 xor B2 xor C3. Because the double parity blocks are correctly distributed it is possible to reconstruct two lost data disks through iterative recovery. For example, B2 could be recovered without the use of any x1 or x2 blocks by computing B3 xor Cp xor 2n = A2, and then A1 can be recovered by A2 xor A3 xor Ap. Finally, B2 = A1 xor C3 xor 1n.
Running in degraded mode with a double parity system is not advised.
Traditional EMC RAID 5 RAID S A1 A2 A3 Ap A1 B1 C1 1p B1 B2 Bp B3 A2 B2 C2 2p C1 Cp C2 C3 A3 B3 C3 3p Dp D1 D2 D3 A4 B4 C4 4p
Note: A1, B1, et cetera each represent one data block; each column represents one disk. A, B, et cetera are entire volumes.
In particular, it supports k-way mirroring on n drives when k does not divide n. This is done by repeating each chunk k times when writing it to an underlying n-way RAID 0 array. For example, 2-way mirroring on 3 drives would look like
A1 A1 A2 A2 A3 A3 A4 A4 A5 A5 A6 A6
This is obviously equivalent to the standard RAID 10 arrangement when k does divide n.
Linux can also create other RAID configurations using the md driver (0, 1, 4, 5, 6) as well as non-raid uses like multipath and LVM2. This md driver should not be confused with the dm driver, which is for IDE/ATA chipset based software raid (ie. fakeraid).
This configuration is tolerant of non-adjacent drives failing. Other storage systems including Sun's StorEdge T3 support this mode as well.