Rumble measurement is carried out on turntables (for vinyl recordings) which tend to generate very low frequency noise originating from the centre bearing and from drive pulleys or belts, as well as from irregularities in the record disc itself.
It can be heard as low-frequency noise, and becomes a serious problem when playing records on audio systems with a good low-frequency response. Even when not audible, rumble can cause intermodulation, modulating the amplitude of other frequencies. The ‘unweighted’ response curve is intended for use in assessing the level of inaudible rumble with such intermodulation in mind.
One way to reduce rumble is to make the turntable very heavy, so that it acts as mechanical damper or low-pass filter, but even with the best turntables a lot of rumble tends to be generated by warped records or pressing irregularities sometimes visible as ‘bobbles’ in the surface. An important factor affecting rumble is low-frequency resonance resulting from pickup arm mass bouncing against stylus compliance. This resonance is usually in the 10–30 Hz region, and will increase rumble as well as reducing tracking ability if not well-damped. Good pickup arms incorporate viscous damping aimed at eliminating such resonance.
Though several standards exist that define how rumble should be measured, they all have a common basis, and use the weighting curves shown here. DIN 45539 (1971) and IEC98-1964 both cover rumble measurement. BS4852: Part 1 (1972) is specific in requiring that a slow rectifier be used, which shall reach 99% of its steady indication in 5s +-0.5s with not more than 10% overshoot.
Audio engineering | Broadcast engineering | Sound production technology | Sound recording | Sound
This article is licensed under the GNU Free Documentation License.
It uses material from the
"Rumble measurement".
Home Page • arts • business • computers • games • health • hospitals • home • kids & teens • news • physicians • recreation• reference • regional • science • shopping • society • sports • world